What was found
CORROSION AFT CARGO BAY SHIELD FWD OF CARGO DOOR AROUND MULTIPLE NUT PLATE HOLES BS767 TO BS794 RBL22 WL156<[01] UPDATED MEASUREMENT TABLE FOR PICTURE OF CORROSION ATTACHED STEP 20;[02] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[03] VERIFIED CORRECTIVE ACTION 2 AND THE MEASUREMENT TABLE.;[04] REMOVED ACB SHIELD FWD OF DOOR; BS767-794; RBL22; IAW SRM 51-40-02-0G-0.;[05] LOCATED AND DRILLED AFT CARGO BAY SHIELD FWD OF CARGO DOOR BS 767 TO 794 RBL 22 WL 156 IAW SRM 51-40-05-0G-0 AND DWG 146A0081;[06] VERIFIED CORRECTIVE ACTION 5.;[07] INSTALLED AFT CARGO BAY SHIELD FWD OF CARGO DOOR BS 767 TO 794 RBL 22 WL 156 IAW SRM 51-40-05-0G-0 AND DWG 146A0081;[08] VERIFIED CORRECTIVE ACTION STEP 7.;[09] VERIFIED MEASUREMENT TABLE AND TASK CARD COMPLETE.