What was found
CRACK WEB LOCATED BTW BS 294.5 TO BS 303.9 STR 16L AT FWD GALLEY AREA 2023-37139<REMOVED AND RE-INSTALLED WEB WEB LOCATED BTW BS 294.5 TO BS 303.9 STR 16L AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DRAWING #141A8180. REV: C. SEE INDIVIDUAL SIGN-OFF BELOW;[03] CORRECTED STEP 1. REMOVED WEB LOCATED BTW BS 294.5 TO BS 303.9 STR 16L AT FWD GALLEY AREA AND FASTENERS IAW B737-700 SRM 51-40-02 RE-INSTALLED WEB IAW B737-700 SRM 51-40-02 AND DRAWING #141A8180. REV: C. SEE INDIVIDUAL SIGN-OFF BELOW;[04] CORRECTED STEP 3. REMOVED WEB LOCATED BTW BS 294.5 TO BS 303.9 STR 16L AT FWD GALLEY AREA AND FASTENERS IAW B737-700 SRM 51-40-02 AND PERFORMED EDDY CURRENT INSPECTION DONE ON WEB FWD GALLEY AREA BTW BS 294.5 TO BS 303.9 STR 16 L AS PER NDT 7373 PART6 51-00-00 PROCEDURE 23.CRACK INDICATION NOT FOUND.TOOL USED PN:NORTEC 600D;PN:200053402;DUE DATE:13-MAY-23. AND RE-INSTALLED WEB IAW B737-700 SRM 51-40-02 AND DRAWING #141A8180. REV: C. SEE INDIVIDUAL SIGN-OFF BELOW;[05] REMOVED WEB LOCATED BTW BS 294.5 TO BS 303.9 STR 16L AT FWD GALLEY AREA AND FASTENERS IAW B737-700 SRM 51-40-02 AND PERFORMED EDDY CURRENT INSPECTION DONE ON WEB FWD GALLEY AREA BTW BS 294.5 TO BS 303.9 STR 16 L AS PER NDT 7373 PART6 51-00-00 PROCEDURE 23.CRACK INDICATION NOT FOUND.TOOL USED PN:NORTEC 600D;PN:200053402;DUE DATE:13-MAY-23. AND RE-INSTALLED WEB IAW B737-700 SRM 51-40-02 AND DRAWING #141A8180. REV: C. SEE INDIVIDUAL SIGN-OFF BELOW<BR>RII