What was found
CORROSION ON FLOOR SUPPORT STA 949; STA 958 LBL 49-LBL 50; WL 208.<[01] SRM 53-70-51-1A-1 IS APPLICABLE ALLOWABLE DAMAGE; UPDATED TABLE.;[02] COMPLETED STEPS 1; 2 CORROSION REMOVAL.;[03] VERIFIED CORROSION REMOVAL- STEPS 1 AND 2;[04] UT INSPECTED BLENDED AREA IAW 737 NDTM PART 4 51-00-00 PROCEDURE 2.<BR>REMAINING MATERIAL THICKNESS IS 0.185' ADJACENT TO 0.205'. <BR>EQUIP USED: <BR>-EPOCH 650 ID: ATS2031 CAL DUE: 03/23;[05] CORRECTION TO CORRECTIVE ACTION 4.<BR><BR>REMAINING MATERIAL THICKNESS STA 949 IS:<BR>0.185' ADJACENT TO 0.205'<BR>0.095' ADJACENT TO 0.145'<BR>0.082' ADJACENT TO 0.085'<BR><BR>REMAINING MATERIAL THICKNESS STA 958 IS:<BR>0.078' ADJACENT TO 0.080';[06] EVALUATED DAMAGE ON FLOOR SUPPORT STA 949; STA 958 LBL 49-LBL 50; WL 208. MAX MATERIAL REMOVED FOUND TO BE 0.050' FROM AREA OF ORIGINAL THICKNESS OF 0.145'. DAMAGE FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1.;[07] VERIFIED CORRECTIVE ACTIONS STEP 6.;[08] PARTIAL STEP 3;[09] VERIFIED STEP 3 PARCIAL;[10] PARTIAL STEPS 1-3;[11] VERIFIED STEPS 1-3;[12] VERIFIED MEASUREMENT TABLE.