What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT LBL45 FWD GALLEY AND LAV 2022-697155<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE AND FASTENERS LOCATED BS312 TO BS328 AT LBL45 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02; SRM 51-40-02 AND DWG 141A5400; SHEET: 26 REV - SEE INDIVIDUALS SIGN OFF BELOW;[02] CORRECTIVE ACTION 1 COMPLETE AND CERTIFIED RII <BR><BR>REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE AND FASTENERS LOCATED BS312 TO BS328 AT LBL45 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02; SRM 51-40-02 AND DWG 141A5400; SHEET: 26 REV - SEE INDIVIDUALS SIGN OFF BELOW