What was found
CRACK STUD FRAME ANGLE LOCATED ON BS294.5 RBL55 WL208.1 AT FWD GALLEY AREA 2022-697211<[01] REPLACED STUD FRAME ANGLE AND FASTENERS LOCATED ON BS294.5 RBL55 WL208.1 AT FWD GALLEY AREA IAW; B737-700 SRM 51-10-02 PARAGRAPH 9; SRM 51-40-02; DRAWING 141A8310 SHEET 25 REV: AND DRAWING 140A9810 SHEET 21 REV: A. SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED STUD FRAME ANGLE AND FASTENERS LOCATED ON BS294.5 RBL55 WL208.1 AT FWD GALLEY AREA IAW; B737-700 SRM 51-10-02 PARAGRAPH 9; SRM 51-40-02; DRAWING 141A8310 SHEET 25 REV: AND DRAWING 140A9810 SHEET 21 REV: A. RII. SEE INDIVIDUAL SIGN OFF BELOW.