What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS344+5 RBL32 WL208.<[01] REMOVED INTERCOSTAL BS 344 TO BS 360 RBL 32 WL 208.1 PER SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED NEW INTERCOSTAL AT FWD WET AREA BS 344 TO BS 360 RBL 32 WL 208.1; IAW SRM 51-40-05-0G-0 AND DWG 141A5410. OK TO INSTALL;[03] INSPECTED ACTION 1;2 OK TO INSTALL;[04] INSTALLED NEW INTERCOSTAL AT FWD WET AREA BS 344 TO BS 360 RBL 32 WL 208.1; IAW SRM 51-40-02-0G-0 AND DWG 141A5400; CARD IS COMPLETED;[05] VERIFIED CORRECTIVE ACTION 4 AND THE MEASUREMENT TABLE.;[06] UPDATED PART REQUIREMENT; SIGNED;[07] WORKSCOPE COMPLETE.