What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS312+9 LBL46 WL208.<[01] EMOVED INTERCOSTAL BS 312 TO BS 328 LBL 46 WL 208.1 PER SRM 51-40-02-0G-0;[02] RECIVED NEW INTERCOSTAL P/N 141A5110-12 LOCATED AND DRILLED NEW INTERCOSTAL AT BS 312 TO BS 328 LBL46 WL208; IAW 737-700 SRM 51-40-05-0G-0 DWG 1421A5410.;[03] CORRECTION DWGV 141A5410;[04] VERIFIED CORRECTIVE ACTION STEPS1;2 AND 3. VERIFIED OK TO INSTALL.;[05] INSTALLED NEW INTERCOSTAL P/N 141A5110-12 AT BS 312 TO BS 328 LBL46 WL208; IAW 737-700 SRM 51-40-02-0G-0 DWG 141A5410 REV A;[06] CORRECTION ON THE DWG # 141A5400 IN LUE OF 141A5410 REV A;[07] VERIFIED CORRECTIVE ACTION 5 AND 6.;[08] VERIFIED THE MEASUREMENT TABLE. WORKSCOPE COMPLETE.