What was found
CORROSION AFT WET AREA TENSION STRAP BS1016 - BS1016+8 LBL 3<[01] DAMAGE FOUND ON AFT WET AREA TENSION STRAP BS 1016+8 LBL 3 FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT STATEMENT ON SRM PARTS WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR.9C;[02] VERIFIED CORRECTIVE ACTION #1.;[03] REMOVED TENSION STRAP FROM AFT WET AREA BS1016 LBL 3 IAW SRM 51-40-02-0G-0;[04] FABRICATED NEW AFT WET AREA TENSION STRAP BS 1016 - 1029 LBL 3 LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG # 147A5600 OK TO TREAT AND PRIME;[05] FABRICATED NEW AFT WET AREA TENSION STRAP BS 1016 - 1029 LBL 3 MATERIAL USED 7075T6 CLAD 0.071' LOT # 1497836-1 LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG # 147A5600 OK TO TREAT AND PRIME;[06] VERIFIED CORRECTIVE ACTION 5. OK TO TREAT AND PRIME.;[07] APPLIED A CHEMICAL CONVERSION COATING AND PRIMER TO THE NEW TENSION STRAP IAW SRM 51-20-01 AND SOPM 20-41-02 ; OK TO INSTALL;[08] VERIFIED CORRECTIVE ACTION7 OK TO INSTALL GIVEN.;[09] INSTALLED THE NEW TENSION STRAP BS 1016 - 1029 LBL 3 WL 208 IAW SRM 51-40-02 AND DWG # 147A5600;[10] VERIFIED CORRECTIVE ACTION 9.;[11] TASK IS COMPLETE.;[12] VERIFIED MEASUREMENT TABLE AND TASK CARD COMPLETE.