What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS312+5 RBL30 WL208.<[01] REMOVED INTERCOSTAL BS 312 TO BS 328 RBL 30 WL 208.1 PER SRM 51-40-02-0G-0;[02] RECIVED NEW INTERCOSTAL P/N 141A5110-12 LOCATED AND DRILLED NEW INTERCOSTAL AT BS 312 TO BS 328 RBL30 WL208; IAW 737-700 SRM 51-40-05-0G-0 DWG 1421A5410.;[03] CORECTION DWG 141A5410;[04] VERIFIED CORRECTIVE ACTION STEPS 1;2 AND 3. VERIFIED OK TO INSTALL.;[05] INSTALLED NEW INTERCOSTAL P/N 141A5110-12 AT BS 312 TO BS 328 RBL30 WL208; IAW 737-700 SRM 51-40-02-0G-0 DWG 141A5410 REV A;[06] CORRECTION ON THE INSTALLATION DWG 141A5400 INLUE OF 141A5410;[07] VERIFIED CORRECTIVE ACTION 5 AND 6.;[08] VERIFIED THE MESUREMENT TABLE. WORKSCOPE IS COMPLETE.