What was found
CORROSION ON FWD CARGO BAY DOOR CUT-OUT SUB-THRESHOLD WEB FROM STA 440+7 TO STA 480+10; RBL 26 TO RBL 29; WL 156.<[01] VERIFIED APPLICABILITY IAW SRM 53-30-15-0L-1 FOR IDENTIFICATION AND SRM 53-30-15-1A-1 FOR ALLOWABLE DAMAGE.<BR>REMOVED CORROSION ON FWD CARGO BAY DOOR CUT-OUT SUB-THRESHOLD WEB<BR>FROM STA 440+7 TO STA 480+10; RBL 26 TO RBL 29; WL 156.<BR><BR>EVALUATED BLENDED AREA L=1.600' W=1.900' ORIGINAL THICKNESS 0.045' REMAINING 0.039' LOSS 0.006'; MAX MAT REMOVED ALLOWED 0.004'; WAS FOUND OUT LIMITS IAW SRM 53-30-15-1A-1 TABLE 101 PARA 4G (2) FIG 103 DETAIL D.<BR>TOOL ID: ATS1672 S/N: 65092939 DUE:03/2023;[02] INSPECTED ACTION 1;[03] VERIFIED MEASUREMENT TABLE;[04] FABRICATED; LOCATED AND DRILLED NEW THRESHOLD WEB IAW SRM 51-40-05-0G-0 AND DWG 143A8330.;[05] THIS PART WILL BE INSTALLED WITH THE CUSTOMER CARD NBR: 5530-E-16461-NG (TTG8Q004GCTG);[06] VERIFIED CORRECTIVE ACTIONS #4 AND #5;[07] MEASUREMENT TABLE VERIFIED