What was found
CRACK ON PASSENGER CABIN FLOOR INTERCOSTAL AT BS 500D+10 BL 0.(MARKED)<[01] DAMAGE FOUND AT PASSENGER CABIN FLOOR INTERCOSTAL UPPER ANGLE FOUND TO BE OUT OFF LIMIT DUE TO NO LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-40-02-0G-0. PAR. 9C;[02] REMOVED PASSENGER CABIN FLOOR INTERCOSTAL UPPER ANGLE BS-500D-TO-BS-520; BL-0; WL 208; IAW SRM 51-40-02-0G-0;[03] VERIFIED CORRECTIVE ACTION 1 AND 2. VERIFIED MEASUREMENT TABLE;[04] LOCATED AND DRILLED NEW ANGLE PER REF SRM 51-40-02-0G-0 <BR><BR>OK TO INSTALL NEW ANGLE;[05] CORRECTION ENTRY NBR 4: REF SRM 51-40-05-0G-0;[06] VERIFIED CORRECTIVE ACTION 4 AND 5. OK TO INSTALL UPPER INTERCOSTAL ANGLE.;[07] INSTALLED NEW ANGLE AT PASSENGER CABIN FLOOR INTERCOSTAL AT BS 500D+10 BL 0. PER REF SRM 51-40-02-0G-0 AND DWG NBR 143A5400;[08] VERIFIED CORRECTIVE ACTION 7;[09] VERIFIED MEASUREMENT TABLE- WORKSCOPE COMPLETE.