What was found
R/W PANEL 661AB HAS PULLED FASTENER HOLES (MARKED)<[01] IDENTIFIED PANEL IAW SRM 57-51-01-0I-1 FIGURE 3 TABLE 3 ITEM 5<BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 57-51-01-1A-1 PAR.4 B(5)<BR><BR>DAMAGE TO BE REPAIRED IAW SRM 51-70-04-2R-9 AS DIRECTED BY SRM 57-51-01-2R-1 PAR.4 C TABLE 202<BR><BR>REMOVED DAMAGE FROM (26EA) FASTENER HOLES; ALL MEASURING 0.5' DIA; CLEANED; WITH NO CONTAMINATION NOTED IAW SRM 51-70-04-2R-9 PAR.4 A-C FIGURE 201;[02] VALIDATED APPLICABILITY OF DAMAGE TO BE REPAIRED IAW SRM 51-70-04-2R-9.;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VERIFIED MEASUREMENTS TABLE<BR><BR>VALIDATED REPAIR PER SRM 51-70-04-2R-9;[04] APPLIED SLURRY MIXTURE OF CHOPPED FIBERS AND LAMINATING RESIN BMS8-301 CL1 LOT#JH2EAA8895 TO FASTENER HOLES; AND SET TO CURE USING HOT BONDER ID: ATS2802 DUE:10/2023 IAW SRM 51-70-04-2R-9 PAR.4 D-F;[05] CURED SLURRY; SANDED FLUSH AND CLEANED REPAIR AREAS IAW SRM 51-70-04-2R-9 PARAGRAPH 4.F-I.;[06] FABRICATED AND INSTALLED REPAIR PLIES USING BMS9-3 ST1581 LOT#1513216-1 AND BMS8-301 CL1 LOT#JH2EAA8895; VACUUM BAGGED; LEAK CHECKED GOOD USING VACUUM GAUGE ID: ATS2802 DUE:10/2023; AND SET TO CURE USING HOT BONDER ID:ATS2802 DUE:10/2023 IAW SRM 51-70-04-2R-9 PAR.4 J-M