What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED BS 695 BL0 CENTER SECTION 2022-708638<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112031023; DUE DATE: 01-FEB-23; TEMPERATURE CONTROLLER P/N: 48VFL11; S/N: AE-31448; DUE DATE: 14-JUN-23.;[02] REPLACED ANGLE AND FASTENERS FLOOR STRUCTURE LOCATED BS 695 BL0 CENTER SECTION IWA B737-700 SRM 51-40-02 AND SRM 51-10-02. SEE INDIVIDUAL SIGN OFF BELOW;[03] REPLACED ANGLE AND FASTENERS FLOOR STRUCTURE LOCATED BS 695 BL0 CENTER SECTION IWA B737-700 SRM 51-40-02 AND SRM 51-10-02. SEE INDIVIDUAL SIGN OFF BELOW<BR>AS RII