What was found
CABIN FLOOR SUPPORT INTERCOSTAL IS CRACKED BETWEEN 328-344 47' LEFT OF CENTER LINE<[01] REMOVED DAMAGED CABIN FLOOR SUPPORT INTERCOSTAL PER REF 51-40-02-0G-0.;[02] INSTALLED EWIS PROTECTION AT FWD CABIN STA 328-344 47' LEFT OF CENTER LINE PER REF AMM 20-60-07-913-801.;[03] VERIFIED STEPS 1 AND 2;[04] OK TO LOCATE AND DRILL HOLES;[05] LOCATED AND DRILLED NEW INTERCOSTAL PER REF SRM 51-40-05-0G-0;[06] VERIFIED STEP 5;[07] OK TO TREAT AND PRIME HOLES;[08] TREATED AND PRIMED PER REF AMM 51-21-41-370-803;[09] VERIFIED STEP 8;[10] OK TO INSTALL INTERCOSTAL;[11] INSTALLED NEW INTERCOSTAL PER REF SRM 51-40-02-0G-0 AND DWG 141A5400;[12] REMOVED AND REPLACED NEW INTERCOSTAL AT MAIN CABIN STA 328-344 47'LEFT OF CENTER LINE PER REF SRM 51-40-02-0G-0 AND DWG 141A5400.;[13] VERIFIED STEPS 11 AND 12