What was found
DOT A24-5 MID CABIN FLOOR PANEL 232SF HAS PULLED COMPOSITE FIBERS ON UPPER SIDE.<[01] EVALUATED AND FOUND MISSING FIBERS ON UPPER SURFACE AFT SIDE OF BOARD. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP 3 A; C; E-F.<BR><BR>APPLIED POTTING COMPOUND IAW SRM 53-00-50-2R-1 STEP 3 G-J. CURED AT 120 DEGREES (AAR 30347 EXP 4-30-23). POTTING COMPOUND (A153169).<BR><BR>REQUEST OK TO BOND;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR IAW SRM 53-00-50-2R-1 STEP 3 K-M. CURED AT 150 DEGREES (AAR 30347 EXP 4-30-23). TAP TEST GOOD.;[04] REPAIRED MID CABIN FLOOR PANEL 232SF UPPER SIDE IAW SRM 53-00-50-2R-1 AND SRM 53-00-50-2R-0 REPAIR GENERAL.;[05] VERIFIED STEPS 3-4