What was found
CRACK ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT ATTACH ANGLE AT LBL 25 BS 400.<[01] REMOVED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT ATTACH ANGLE AT LBL 25 BS 400 PER SRM 51-40-02-0G-0.;[02] CRACK ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT ATTACH ANGLE AT LBL 25 BS 400 WITH NEXT DIMENSIONS L=0.130 TOOL USED ID: ATS1317; SN: UNKNOWN; DATE:08/2022; DUE:08/2023 FOUND TO BE OUT LIMITS DUE TO NO ALLOWABLE DAMAGE IN SRM; IT WILL BE REPAIRABLE BY REPLACEMENT I.A.W SRM 51-10-02-0G PAR 9C.;[03] LOCATED AND DRILLED NEW ATTACH ANGLE ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 25 BS 400 I.A.W SRM 51-40-05-0G-0 AND DWG 143A7505.AND OK TO INSTALL.;[04] VERIFIED MEASUREMENTS<BR>VERIFIED CORRECTIVE ACTION #2; 3;[05] INSTALLED NEW ATTACH ANGLE ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 25 BS 400 I.A.W SRM 51-40-02-0G-0 AND DWG 143A7505.;[06] VERIFIED CORRECTIVE ACTION #5