What was found
CRACK ON FWD CARGO BAY GUSSET AT BS 500D STRINGER 19L.<[01] DAMAGE FOUND AT FWD CARGO BAY GUSSET BS 500D STR-19L FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT ON SRM PARTS WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR.9C.;[02] VERIFIED CORRECTIVE ACTION #1 AND MEASUREMENT FIELD;[03] REMOVED FWD CARGO BAY GUSSET AT BS 500D STRINGER 19L IAW SRM 51-40-02;[04] LOCATED AND DRILLED FWD CARGO BAY NEW GUSSET AT BS 500D STRINGER 19L P/N143A9481-6 IAW SRM 51-40-05 AND DWG 143A9481 REV A ;OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION STEP 4. VERIFIED OK TO INSTALL.;[06] INSTALLED ON FWD CARGO BAY NEW GUSSET AT BS 500D STRINGER 19L P/N143A9481-6 IAW SRM 51-40-02AND DWG 143A7902 REV:;[07] VERIFIED CORRECTIVE ACTION STEP 6.;[08] VERIFIED MEASUREMENT TABLE AND TASK CARD COMPLETE.