What was found
CRACK ANGLE FLOOR STRUCTURE BS 695 RBL 24.82 CENTER SECTION 2023-109513<[01] TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112031023; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24.;[02] REPLACED ANGLE LOCATED AT BSTA 695 RBL 24.82 CENTER SECTION IAW SRM B737-700 51-40-02; SRM 51-10-02 AND DWG 273A9110 REV-A; AND DWG 111A6002 REV-A.<BR>SEE INDIVIDUAL SIGNOFFS BELOW;[03] CORRECTIVE ACTIONS RII