What was found
CUSTOMER REQUESTS CRACK ON APU COMPARTMENT CUTOUT STRUCTURE RH SIDE AT LEVEL BSTA 1104 2023-109521<[01] TOOL USED EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 220272712; DUE DATE: 17-DEC-23.;[02] TOOL USED EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 220272712; DUE DATE: 17-DEC-23.;[03] REPAIRED APU COMPARTMENT CUTOUT STRUCTURE RH SIDE AT LEVEL BSTA 1104 IAW SRM B737-700 53-80-01-2R-1 REPAIR 1<BR>SEE INDIVIDUAL SIGNOFFS BELOW;[04] TASK COMPLETED; RII <BR><BR>SEE INDIVIDUAL SIGN OFFS BELOW