What was found
CRACK ON FWD CARGO BAY GUSSET AT BS 500D STRINGER 19L.<[01] NO FOUND ALLOWABLE DAMAGE LIMITS ON SRM; MUST BE REPLACED IAW SRM 51-10-02 PARAGRAPH 9;[02] REMOVED GUSSET IAW SRM 51-40-02;[03] UPDATED MEASUREMENTS PARAMETERS;[04] LOCATED AND DRILLED NEW GUSSET AT B/S 500D STRINGER 19L P/N 143A9481-6 LOT# 1504017-6 IAW SRM 51-40-05 AND DWG 143A7902 REV:- OK TO INSTALL;[05] VERIFIED STEP 1; 3 AND 4 ; OK TO INSTALL GIVEN.;[06] INSTALLED NEW GUSSET AT B/S 500D STRINGER 19L P/N 143A9481-6 IAW SRM 51-40-02 AND DWG 143A7902 REV:-;[07] VERIFIED MEASUREMENTS<BR>VERIFIED CORRECTIVE ACTION #6