What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 460+10; BS 480+14; BS 500+10; BS 500+14; BS 500A+6; BS 500A+10.<[01] SRM 53-00-53-1A-2 IS FOUND TO BE APPLICABLE. EVALUATED 6 SPOTS OF CORROSION FROM BS460+10 - BS500A+10 THE DEEPEST SPOT IS .6L X .6W Y.010. ORIGINAL THICKNESS IS 0.040; REMINING THICKNESS IS 0.030. PART IS OUT OF LIMITS. IAW SRM 53-00-53-1A-2<BR>CAL TOOL ID: ATS2595 SER#F03295 EXP: 02/2023;[02] VERIFIED CORRECTIVE ACTION #1;[03] VERIFIED ITEM 1 CORRECTIVE ACTIONS.;[04] JOB WILL BE ACCOMPLISH ON CUSTOMER CARD NBR: TTG8Q00HF0G0;[05] FIXED MEASUREMENT CHART;[06] VERIFIED MEASUREMENTS<BR>VERIFIED CORRECTIVE ACTION #4