What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500A+6; BS 500A+10; BS 500A+14; BS 500B+6; BS 500B+10; BS 500C+14.<[01] SRM 53-00-53-1A-2 IS FOUND TO BE APPLICABLE. EVALUATED 6 SPOTS OF CORROSION FROM BS500A+2 - BS500C+14 THE DEEPEST SPOT IS .6L X .4W Y.018. ORIGINAL THICKNESS IS 0.040; REMINING THICKNESS IS 0.022. PART IS OUT OF LIMITS. IAW SRM 53-00-53-1A-2<BR>CAL TOOL ID: ATS2595 SER#F03295 EXP: 02/2023;[02] VERIFIED CORRECTIVE ACTION #1;[03] FABRICATED; LOCATED AND DRILLED NEW FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 FROM BS 500A TO BS 500D; FROM BAC1496-444#7075T62; LOT#1515896-1; IAW SRM 51-40-05-0G-0; S; DWG 143A7501; ID:0113; REV: -; APPLIED CHEMICAL CONVERSION IAW AMM 51-21-41-370-802; REQUEST OK TO APPLY PRIMER;[04] OK TO APPLY PRIMER.CORRECTIVE ACTION 3.;[05] APPLIED PRIMER ON NEW FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT IAW AMM 51-21-72-370-804;[06] VERIFIED CORRECTIVE ACTIONS STEP 5.;[07] VERIFIED MEASURMENT TABLE AND ALL STEPS COMPLETE