What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT FROM STA 727A+1 TO STA 787+7; LBL 20 TO 22; WL 156<[01] REMOVED CORROSION FROM ACB FLOOR TO SIDEWALL SUPPORT FROM STA. 727A + 1' TO STA. 787 +7'; LBL 20 TO 22; WL 156 IAW SRM 51-10-02-0G-0; PARR 6.<BR>BLENDED AREAS MEASUREMENTS:<BR>BS 727A +1': L = 0.900'; W = 0.600'; D = 0.003'.<BR>BS 727B - 2': L = 1'; W = 0.800'; D = 0.002'.<BR>BS 727B + 10': L = 1.100'; W = 0.800'; D = 0.002'.<BR>BS 727C - 2': L = 0.700'; W = 0.700'; D = 0.002'.<BR>BS 727C + 2': L = 1.100'; W = 1.000'; D = 0.002'.<BR>BS 727C + 6': L = 1.400'; W = 0.900'; D = 0.005'; AND FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2; [07] PARTIAL UPDATE STEP 2.;[08] PARTIAL UPDATE STEP 2.;[09] PARTIAL UPDATE STEP 2.;[10] PARTIAL UPDATE STEP 2.;[11] UPDATED MEASUREMENT TABLE;[12] UPDATED STEP 1;[13] COMPLETED STEP 1.<BR>PROVIDED PARTIAL UPDATE TO STEP 2.;[14] PARTIAL UPDATE STEP 2.;[15] PARTIAL UPDATED STEP 2.;[16] ALL STEPS COMPLETE;[17] VERIFIED ALL STEPS COMPLETE;[18] VERIFIED MEASUREMENT TABLE