What was found
CORROSION ON AFT PASSENGER CABIN STRAP AT RBL 2.5 BS 1016+12<[01] CORROSION ON STRAP AT BS 1016+12; RBL 2.5; WL 208 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS GIVEN IN THE SRM.<BR>REMOVED STRAP PER SRM 51-40-02;[02] REMOVED DAMAGED STRAP IAW SRM CH 51-40-02.;[03] LOCATED AND DRILLED NEW STRAP IAW SRM CH 51-40-05. OK TO INSTALL.;[04] VERIFIED CORRECTIVE ACTIONS STEPS 1;2;3 OK TO INSTALL GIVEN .;[05] VERIFIED MEASUREMENTS TABLE.;[06] INSTALLED STRAP IAW SRM CH 51-40-02 AND DRAWING # 147A5730 SHEET 21.;[07] RII VERIFIED CORRECTIVE ACTION ITEM 6.;[08] VERIFIED CORRECTIVE ACTION ITEMS AND MEASUREMENT FIELDS; CARD COMPLETE.