What was found
CORROSION ON LAV A FLOOR MOUNT INTERCOSTAL STA 304-305; LBL 10; WL 208.<[01] UPDATED MEASUREMENT TABLE;[02] EVALUATED CORROSION ON LAV A FLOOR MOUNT INTERCOSTAL STA 304-305; LBL 10; WL 208. FOUND TO HAVE 100% MATERIAL LOSS; .700' BY .600'; OUT OF LIMITS PER SRM 53-10-51-1A-1.;[03] VERIFIED CORRECTIVE ACTION 1 AND 2 AND THE MEASUREMENT TABLE.;[04] LOCATED AND DRILLED NEW LAV A FLOOR MOUNT INTERCOSTAL STA 294- STA 312; LBL 10; WL 200-208 PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; DWG# 141A5600 REV N. OK TO INSTALL.;[05] SIGNED PART TABLE;[06] VERIFIED CORRECTIVE ACTION 4 AND 5 WITH OK TO INSTALL GIVEN;[07] INSTALLED NEW LAV A FLOOR MOUNT INTERCOSTAL STA 294- STA 312; LBL 10; WL 200-208 PER SRM 51-40-02-0G-0; DWG# 141A5600 REV N.;[08] COMPLETED STEP 1;[09] VERIFIED CORRECTIVE ACTION 7.<BR>COMPLETED STEP 1;[10] COMPLETED STEPS 2-5;[11] COMPLETED STEPS 2-6.;[12] COMPLETED STEPS 2-6;[13] COMPLETED STEPS 2; 3; AND 5;[14] COMPLETED STEPS 4 AND 6