What was found
CRACKED INTERCOSTAL ATTACH ANGLE BETWEEN STA 380-400; LBL 13; WL 208.<[01] UPDATED MEASUREMENT TABLE;[02] REMOVED CRACKED INTERCOSTAL ATTACH ANGLE BETWEEN STA 380-400; LBL 13; WL 208 PER SRM 51-40-02-0G-0.;[03] LOCATED AND DRILLED NEW INTERCOSTAL ATTACH ANGLE BETWEEN STA 380-400; LBL 13; WL 208 PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; DWG# 143A5400. OK TO INSTALL.;[04] VERIFIED CORRECTIVE ACTION STEP 3. VERIFIED OK TO INSTALL.;[05] INSTALLED NEW ATTACH ANGLE BETWEEN STA 380-400; LBL 13; WL 208 PER SRM 51-40-02-0G-0 AND DWG 143A5400;[06] VERIFIED CORRECTIVE ACTION 5 AND MEASUREMENT TABLE;[07] JOB COMPLETE