What was found
BREAK PANEL CRACKED AT STA 540; LBL 1; WL 207.<[01] REMOVED DAMAGED BREAKE PANEL AT STA 540 LBL 1; WL 207 IAW SRM 51-40-02-0G-0.;[02] NO ALLOWABLE DAMAGE FOUND ON SRM PART TO BE REMOVED AND REPLACED I.A.W SRM 51-10-02-0G-0 PAR 9.C REPLACEMENT OF THE PART;[03] LOCATED AND DRILLED NEW PANEL BREAK IAW BOIEING DRAWING 143A0060 AND SRM. 51-10-05-OG-0. OK TO INSTALL.;[04] CERTIFIED ITEM 1-3;[05] VERIFIED CORRECTIVE ACTION #2 AND #3<BR>OK TO INSTALL GIVEN;[06] CORRECTIVE ACTION 3 SHOULD READ <BR>LOCATED AND DRILLED NEW PANEL BREAK IAW BOEING DRAWING 143A0060 AND SRM. 51-40-05-OG-0. OK TO INSTALL.;[07] INSTALLED NEW PANEL BREAK IAW BOEING DRAWING 143A0060 AND SRM. 51-40-02-0G-0.;[08] VERIFIED CORRECTIVE ACTION 6 AND #7<BR>MEASUREMENT TABLE VERIFIED