What was found
CRACKED WIRE SUPPORT ANGLE COMMON TO 867 FRAME AT STR 3R.<[01] REMOVED CRACK DAMAGED SUPPORT ANGLE COMMON TO BS 867 RBL 15 WL 301 TO 305 STR 3 R/H IAW SRM 51-40-02-0G-0 NO DAMAGE LIMITS GIVEN IN SRM PART IS REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 LOCATED AND DRILLED NEW SUPPORT ANGLE IAW SRM 51-40-05-0G-0 OK TO INSTALL;[02] VERIFIED CORRECTIVE ACTION 1 WITH OK TO INSTALL AND MEASUREMENT TABLE;[03] INSTALLED WIRE SUPPORT BRACKET AT BS 867 FRAME RBL 15 WL 301 TO 305 IAW SRM 51-40-02-0G-0 AND AIPC 53-42-51-56 OK TO INSTALL DISPLACED WIRING; INSULATION AND TUBE.;[04] VERIFIED CORRECTIVE ACTION 3 OK TO INSTALL DISPLACED WIRING; INSULATION AND TUBE GIVEN;[05] RELOCATED DISPLACED INSULATION BLANKETS AT BS 867 RBL 15 WL 301 TO 305 IAW AMM 25-80-00-400-801. INSTALLED WIRING AND TUBE IAW SOPM 20-50-01;[06] VERIFIED CORRECTIVE ACTION 5