What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE BTW STA 277 TO STA 294.5 AND BL 0 FWD GALLEY AND LAV 2023-112817<[01] REPLACED INTERCOSTAL WEB LOCATED ON FLOOR STRUCTURE BTW STA 277 TO STA 294.5 AND BL 0 FWD GALLEY AND LAV I.A.W. B737-700 SRM 51-40-02 AND DWG 141A5400 REV. -. SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED INTERCOSTAL WEB LOCATED ON FLOOR STRUCTURE BTW STA 277 TO STA 294.5 AND BL 0 FWD GALLEY AND LAV I.A.W. B737-700 SRM 51-40-02 AND DWG 141A5400 REV. -. SEE INDIVIDUAL SIGN OFF BELOW. RII