What was found
FLOOR SUPPORT HAS A CRACK BS 540 LBL 44<[01] VERIFIED APPLICABILITY NOT ALLOWABLE ITEMS THAT DO NOT HAVE ENTRIES ARE CALLEDREPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED FLOOR SUPPORT AT BS 540 LBL 25 TO LBL45 IAW SRM 51-40-02;[03] RECEIVED NEW FLOOR SUPPORT AT BS 540 LBL25 TO LBL45 P/N 143A5240-32 PO#905537. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG 143A5240.<BR>OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTION ITEM 3; OK TO INSTALL.;[05] INSTALLED FLOOR SUPPORT AT BS 540 LBL25 - LBL45 IAW SRM 51-40-02 AND DWG 143A0060;[06] VERIFIED CORRECTIVE ACTION 5 AND THE MEASUREMENT TABLE.