What was found
MAIN CABIN AFT WET AREA FLOOR STRAP CORROSION AT RBL 18' STA 1060+10' MAIN CABIN AFT WET AREA FLOOR STRAP CORROSION AT RBL 18' STA 1006 + 10'<[01] FOUND EXFOLIATING CORROSION TO BE OUT OF LIMITS REF SRM 51-70-15-1A-1. PART NEEDS REPLACEMENT.;[02] REMOVED MAIN CABIN AFT WET AREA FLOOR STRAP AT RBL 18'' STA 1060 + 10' REF SRM 51-40-02-0G-0;[03] REMOVED MAIN CABIN AFT WET AREA FLOOR STRAP AT RBL 18'' STA 1006 + 10' REF SRM 51-40-02-0G-0;[04] LOCATED; DRILLED AND COUNTERZUNK HOLES AT AFT WET AREA NEW STRAP AT RBL 18' BETWEEN STA 1006 + 10' REF 51-40-05-0G-0;[05] CORRECTION TO STEP 2 AND 3: REMOVED MAIN CABIN AFT WET AREA FLOOR STRAP AT RBL 18'' STA 1006 + 10' REF SRM 51-40-02-0G-0;[06] VERIFIED STEP 1;4 AND 5. OK TO INSTALL FLOOR STRAP AT RBL 18 AND BETWEEN STA 1006+10.;[07] INSTALLED MAIN CABIN AFT WET AREA FLOOR STRAP AT RBL 18'' STA 1006 + 10' REF SRM 51-40-02-0G-0 AND DWG 147A5730;[08] VERIFIED AND INSPECTED STEP #7. FINAL.;[09] VERIFIED.