What was found
FWD CARGO BAY - SIDEWALL SUPPORT HAS CORROSION BS 500C+13 RBL 23<[01] VERIFIED APPLICABILITY SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.;[02] REMOVED CORROSION ON FWD CARGO BAY SIDEWALL SUPPORT AT RBL 23 BS 500C+13 IAW SRM 51-10-02.<BR><BR>EVALUATED BLENDED AREA L=0.900' W=0.700' ORIGINAL THICKNESS 0.040' PER BAC1496-444 REMAINING 0.025' LOSS 0.015'; MAX MAT REMOVE ALLOWABLE 0.004'; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 PARA 4A (2) FIG 103 DETAIL D<BR><BR>TOOL ID: ATS1671 S/N: 65093024 DUE:07/2023;[03] VERIFIED ACTIONS 1 AND 2;[04] FABRICATED NEW FLOOR TO SIDEWALL SUPPORT BS500A - BS500D; RBL 23; BAC1496-444#7075T6; LOT# 1515896-1; PER SRM 51-40-05 AND DWG 143A7501.;[05] VERIFIED CORRECTIVE ACTION 4 AND MEASUREMENT TABLE;[06] APPLIED CHEMICAL CONVERSION COATING AND PRIMER ON NEW PART; PER SRM 51-20-01 AND SOPM 20-41-02.;[07] VERIFIED CORRECTIVE ACTION 6.;[08] UPDATE CORRECTIVE ACTION 7.