What was found
FWD CABIN FLOOR PANEL 221GF HAS BROKEN TANG ON FWD O/B END<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-6.<BR>REMOVED 7EA THROUGH INSERTS TO FACILITATE REPAIRS IAW SRM 53-00-50-2R-6 PARA 3.B.<BR>REMOVED DAMAGED SKINS AND CORE AND CLEANED REPAIR AREA IAW SRM 53-00-50-2R-6 PARA 3C-F.;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-6.;[03] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 1 AND 2.<BR><BR>VERIFIED MEASUREMENTS TABLE.;[04] FABRICATED CORE PLUG USING BMS 8-124C4T5G9 LOT#1287137 AND UPPER SURFACE REPAIR PLIES USING BMS 9-3H2 LOT#1495277-1 IAW SRM 53-00-50-2R-6 PARA 3F-G.<BR>OK TO INSTALL.;;[10] INSTALLED LOWER REPAIR PLIES USING BMS 8-201TY3 LOT#AK2EP8210K; VACUUM BAGGED; LEAK CHECK GOOD WITH VACUUM GAUGE ID:ATS2797 CAL DUE 10/2023 IAW SRM 53-00-50-2R-6 PARA 3K-L.