What was found
FWD CABIN FLOOR PANEL 222BF HAS A DELAMINATION ON O/B EDGE APPROXIMATELY 4' AFT OF FWD EDGE<[01] IDENTIFIED 222BF PANEL IAW SRM 53-00-50-0I-1 PARA FIGURE 2; TABLE 2.<BR><BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR><BR>WILL BE PERFORMING WORK IAW SRM 53-00-50-2R-1 <BR><BR>LIGHTLY SANDED DAMAGED SURFACE; CLEANED; AND PREPARED FOR REPAIR IAW SRM 53-00-50-2R-1 PARA 3.A-F.;[08] FILLED EXPOSED CELLS USING BMS 5-28 TY19 LOT: AK2JP8366K<BR>CURED POTTING COMPOUND USING THERMOMETER ATS2209 DUE: 10/2023<BR>LIGHTLY SANDED POTTING COMPOUND SMOOTH. CLEANED AND PREPARED PANEL SURFACE FOR REPAIR PLIES.<BR>FABRICATED REPAIR PLIES USING BMS 9-3 TYH2 LOT: 1513216-1 IAW SRM 53-00-50-2R-1 PARA 3.G-K;[09] OK TO INSTALL REPAIR PLIES.;[10] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 8 AND 9. OKAY TO INSTALL REPAIR PLIES.;[11] INSTALLED REPAIR PLIES USING RESIN BMS 8-201 TY3 LOT: AK2EP8210K<BR>ASSEMBLED VACUUM BAG USING VACUUM GAUGE ATS2441 DUE: 08/2023 IAW SRM 53-00-50-2R-1 PARA 3.K-L.(1).(A)<BR><BR>STILL NEEDS 5X5 TEST.;