What was found
SMALL TRANSITION ANGLE JUST AFT OF AFT CARGO DOOR CUTOUT HAS CORROSION AROUND FASTENER HOLES.<[01] REMOVED CORROSION ON TRANSITION ANGLE SHIELD; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] REMOVED TRANSITION ANGLE FASTENERS PER SRM 51-40-02.;[03] VERIFIED CORROSION ON TRANSITION ANGLE SHIELD; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. VERIFIED REMOVAL OF TRANSITION ANGLE SHIELD FOR REPLACEMENT. SIGN OFF FOR CORRECTIVE ACTION 1 AND 2.;[04] REMOVED TRANSITION ANGLE PER SRM 51-40-02.;[05] LOCATED HOLES AND COUNTERSANK NEW TRANSITION ANGLE PER SRM 51-40-02.;[06] INSPECTED WORK PERFORMED ON C/A #5;[07] INSTALLED FASTENERS ON THE NEW TRANSITION ANGLE PER SRM 51-40-02.;[08] C/W INSP .INSTALLED FASTENERS ON THE NEW TRANSITION ANGLE PER SRM 51-40-02.