What was found
CABIN FLOOR PANEL 242E UPPER SURFACE IS DELAMINATED.<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1.<BR>REMOVED DAMAGE SKINS PLIES; CLEANED REPAIR AREA AND FABRICATED REPAIR PLIES USING BMS 9-3 ST1581 LOT#1513216-1 IAW SRM 53-00-50-2R-1 PARA 3.C;E-F;K.<BR>OK TO INSTALL;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-1;[03] RII BUYBACK FOR CORRECTIVE ACTIONS 1 AND 2. INSPECTED AND VERIFIED. <BR><BR>VERIFIED MEASUREMENTS TABLE.;[04] INSTALLED REPAIR PLIES USING BMS 8-201TY3 LOT#AK2EP8210K; VACUUM BAGGED; LEAK CHECK GOOD WITH VACUUM GAUGE ID:ATS2107 CAL DUE 04/2023 IAW SRM 53-00-50-2R-1 PARA 3K;L.;[05] RII BUYBACK FOR CORRECTIVE ACTION 4. 5X5 LEAK CHECK PASSED.;[06] CURED REPAIR PLIES AND UNBAGGED IAW SRM 53-00-50-2R-1 PARA 3.M.<BR>USED THERMOMETER ID:ATS2208 CAL DUE 10/2023;[07] FINAL INSPECTION AND RII BUYBACK FOR FLOOR PANEL REPAIR. JOB COMPLETE.;[08] FINAL INSPECTION AND RII BUYBACK FOR FLOOR PANEL REPAIR. JOB COMPLETE.