What was found
CABIN FLOOR PANEL 241XF HAS SURFACE DELAMINATION.<[01] IDENTIFIED PANEL IAW SRM 53-00-50-0I-1 FIGURE 6 TABLE 6.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>REMOVED 7EA INSERTS AND 6EA BLIND INSERTS TO FACILITATE REPAIR; REMOVED DAMAGE SKIN; AND CLEANED REPAIR AREA IAW SRM 53-00-50-2R-1 PARA 3.A-C;E AND F.;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-1.;[03] RII BUYBACK OF CORRECTIVE ACTIONS 1 AND 2.<BR><BR>VERIFIED MEASUREMENTS TABLE.;[04] FABRICATED REPAIR PLIES FROM BMS9-3 ST1581 LOT#1513216-1 IAW SRM 53-00-50-2R-1 PAR.3 K(1)(A)<BR><BR>OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4<BR><BR>OK TO INSTALL REPAIR PLIES;[06] INSTALLED REPAIR PLIES USING BMS8-201 TY 3 LOT#AK2CP8139K; VACUUM BAGGED; LEAK CHECKED GOOD USING VACUUM GAUGE ID:ATS2107 DUE:04/2023 IAW SRM 53-00-50-2R-1 PAR.3 K(1)(B-C) & L(1)