What was found
FWD CARGO COMPARTMENT RT TRANSITION ANGLE HAS AREAS OF CORROSION FROM STA 500A-500B<[01] R/H TRANSITION ANGLE OUT OF ALLOWABLE LIMITS PER SRM 53-00-53-1A-2. REMOVED R/H TRANSITION ANGLE FROM STA 500A TO 500I PER SRM 51-40-02.;[02] C/W INSPECTION.;[03] FABRICATED NEW R/H TRANSITION ANGLE FROM STA. 500A-500I AND REPAIR PARTS PER SRM 53-00-53-2R-5;[04] FABRICATED SHIMS PER EA M-22-153-01550; TREATED AND PRIMED ALL PARTS PER SOPM 20-41-02;[05] CW;[06] OK TO INSTALL R/H TRANSITION ANGLE;[07] INSTALLED NEW R/H TRANSITION ANGLE STA. 500A-500I PER SRM 53-00-5302R-5 AND EA. M-22-153-01550;[08] INSTALLED NEW R/H TRANSITION ANGLE STA. 500A-500I PER SRM 53-00-53-2R-5 AND EA. M-22-153-01550;[09] INSTALLED CLICK BOND NUTPLATES ON NEW R/H TRANSITION ANGLE FROM STA 500A-500I PER SRM 51-40-10-2R-0.;[10] VERIFIED INSTALLED CLICK BOND NUTPLATES ON NEW R/H TRANSITION ANGLE FROM STA 500A-500I PER SRM 51-40-10-2R-0 CORRECTIVE ACTION 9.