What was found
CORROSION ON FLOOR SUPPORT STA 952; LBL 30; LBL 35; WL 208.<[01] COMPLETED STEP 1; SRM 51-10-02-0G-0 REPLACEMENT OF PART IS APPLICABLE.;[02] COMPLETED STEP 2;[03] STEPS 1;2 PARTIAL UPDATED.;[04] LOCATED AND DRILLED NEW FLOOR SUPPORT STA 952; LBL 24- LBL 49; WL 208 IAW SRM 51-40-05-0G-0 AND DWG 147A5650. INSTALLATION TO BE PERFORMED UNDER FLOOR BEAM REPAIR TTG8Q00J0H2W STEP 6.;[05] VERIFIED ITEM 4 CORRECTIVE ACTIONS.;[06] VERIFIED STEP 1 AND 2.