As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK STIFFENER FLOOR STRUCTURE LOCATED BS 540 BETWEEN BL 0 AND RBL 24.5 WL 208.1 CENTER SECTION 2023-106058<[01] REPLACED STIFFENER FLOOR STRUCTURE LOCATED BS 540 BETWEEN BL 0 TO RBL 24.5 WL 208.1 CENTER SECTION IAW B737-700 #DWG-143A0060 SHEET= 36 REV= A AND SRM 51-40-02;[02] CERTIFIED WORK PERFORMED RII <BR>SEE INDIVIDUAL SIGNOFFS BELOW