What was found
CRACK ON PASSENGER CABIN FLOOR SUPPORT AT BS 540 RBL 2.<[01] NOT ALLOWABLE DAMAGE FOUND ON SRM PART THAT DO NOT ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED FLOOR SUPPORT ON BS 540 RBL 2 IAW SRM 51-40-02;[03] RECEIVED ON FWD CABIN FLOOR SUPPRT ON BS 540 RBL 2 P/N 143A5240-35. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG 143A0060.<BR>OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTIONS STEP 3 OK TO INSTALL GIVEN.;[05] INSTALLED NEW FLOOR SUPPORT ON BS 540 RBL 2 P/N 143A5240-35 ON FWD CABIN I.A.W SRM 51-40-02-0G-0 AND DWG 143A0060.;[06] VERIFIED CORRECTIVE ACTIONS STEP 5; AND MEASUREMENTS TABLE.