What was found
CRACK ON PASSENGER CABIN FLOOR SUPPORT AT BS 540 LBL 2.<[01] NOT ALLOWABLE DAMAGE FOUND ON SRM PART THAT DO NOT ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED FLOOR SOPPORT ON PASSENGER CABIN FLOOR SUPPORT AT BS 540 LBL 2IAW SRM 51-40-02;[03] RECEIVED ON PASSENGER CABIN FLOOR SUPPORT AT BS 540 LBL 2 P/N 143A5240-36. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG 143A0060.<BR>OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTIONS STEP 3 OK TO INSTALL GIVEN.;[05] INSTALLED NEW FLOOR SUPPORT ON BS 540 LBL 2 P/N 143A5240-36 ON FWD CABIN I.A.W SRM 51-40-02-0G-0 AND DWG 143A0060.;[06] VERIFIED CORRECTIVE ACTIONS STEP 5 AND MEASUREMENTS TABLE.