What was found
CRACK ON PASSENGER CABIN FLOOR SUPPORT AT BS 540 LBL 26.<[01] NOT ALLOWABLE DAMAGE FOUND ON SRM PART THAT DO NOT ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED FLOOR SUPPORT ON PASSENGER CABIN AT BS 540 LBL 26 IAW SRM 51-40-02;[03] RECEIVED ON FWD CABIN NEW FLOOR SUPPORT ON BS 540 LBL 26 P/N 143A5240-32. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG 143A0060.<BR>OK TO INSTALL;[04] OK TO INSTALL GIVEN; VERIFIED CORRECTIVE ACTIONS STEP 3.;[05] INSTALLED NEW FLOOR SUPPORT ON BS 540 LBL 26 P/N 143A5240-32 ON FWD CABIN I.A.W SRM 51-40-02-0G-0 AND DWG 143A0060.;[06] VERIFIED CORRECTIVE ACTIONS STEP 5.;[07] VERIFIED MEASUREMENTS TABLE.;[08] CERTIFY