What was found
FRAME CRACKED BS400 R/H AT BIN RAIL ATTACH POINT BETWEEN STR8R-9R. ACCOMPLISHED HFEC SURFACE SCAN IAW NDTM PART 6 CHAPTER 51-00-00 PROCEDURE 23. VERIFIED MULTIPLE CRACKS AROUND HOLE MEASURED 1.6' L AND 0.6'L. REMOVED DAMAGE ON FRAME BS 400 R/H AT BIN RAIL ATTACH POINT BTW S-8R - S-9R; CUT OUT AREA: L= 1' X W=.850' IAW SRM 51-10-02-0G-0. REQ NDI CUT OUT FOR FREE CRACK CONDITION. HFEC INSPECTED CUTOUT AREA IAW NDTM PART 6 51-00-00 PROCEDURE 23.NO CRACKS NOTED. REPAIRED PER EA 23-153-00830.