What was found
FRAME CRACKED BS400 R/H AT BIN RAIL ATTACH POINT BETWEEN STR8R-9R<[01] VERIFY CRACK LENGTH BY NDI HFEC PROCEDURE.;[02] ACCOMPLISHED HFEC SURFACE SCAN IAW 737 NDTM PART 6 CHAPTER 51-00-00 PROCEDURE 23. VERIFIED MULTIPLE CRACKS AROUND HOLE MEASURED 1.6' L AND 0.6'L MARKED.<BR><BR>EQUIPMENT USED: NORTEC 600 ID: ATS1465 CAL DUE: 09/2023;[03] REMOVED DAMAGE ON FRAME BS 400 R/H AT BIN RAIL ATTACH POINT BTW S-8R - S-9R; CUT OUT AREA: L= 1' X W=.850' IAW SRM 51-10-02-0G-0;[04] VERIFIED CORRECTIVE ACTION 3.;[05] REQ NDI CUT OUT FOR FREE CRACK CONDITION;[06] HFEC INSPECTED CUTOUT AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>NO CRACKS NOTED.<BR>EQUIP USED:<BR>-NORTEC 600 ID: ATS1465 CAL DUE: 09/23;[07] REPAIRED PER EA 23-153-00830