What was found
INTERCOSTAL CRACKED AT CTR HOLE; BS380-400; BL-0; WL 206;<[01] NOT ALLOWABLE DAMAGE FOUND ON SRM PART THAT DO NOT ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED INTERCOSTAL ON BS 380-400; BL-0; WL 206 IAW SRM 51-40-02;[03] RECEIVED ON FWD CABIN NEW INTERCOSTAL ON BS380-400; BL-0; WL 206 P/N 143A5410-170. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG 143A5400.<BR>OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTION 3.;[05] INSTALLED ON FWD CABIN INTERCOSTAL ON BS380-400; BL-0; WL206 IAW SRM 51-40-02 AND DWG 143A5400;[06] UPDATE MEASUREMENT TABLE;[07] VERIFIED CORRECTIVE ACTION 5 AND MEASUREMENT TABLE.