What was found
CORROSION ON PASSENGER CABIN FLOOR STRAP AT BS 1016+12 RBL 17.<[01] CORROSION ON PASSENGER CABIN FLOOR STRAP AT BS 1016+12 RBL 17 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN THE SRM FOR THIS ITEM AND IT IS REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 .;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED CABIN FLOOR STRAP AT BS 1016+12 RBL 17 IAW SRM 51-40-02;[04] OBTAINED LOCATED AND DRILLED NEW PASSENGER CABIN FLOOR STRAP AT BS 1016-1029 RBL 17 IAW SRM 51-40-05 AND DWG # 147A5714 ; OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4.;[06] INSTALLED NEW PASSENGER CABIN FLOOR STRAP AT BS 1016 - 1029 RBL17 IAW SRM 51-40-02 AND DWG #147A5714;[07] VERIFIED CORRECTIVE ACTION 6 AND MEASUREMENT TABLE.