As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500A+2-BS 500C+14.<[01] PARTIAL STEP 1 AND 2.;[02] PARTIAL STEP 1 AND 2; OUT OF LIMITS;[03] RECEIVED CHANNEL ASSY. WITH P/N 143A7501-186 LOT.1509736-1. LOCATED AND DRILLED NEW PART BTW BS 500A - BS 500D IAW SRM 51-40-05 AND DWG# 143A7500.;[04] COMPLETED STEPS 1 AND 2 AND CORRECTIVE ACTION 3. VERIFIED MEASUREMENT TABLE.