What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED BS 695 BL 0 CENTER SECTION 2023-142550<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112031023; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24.;[02] REPLACED ANGLE FLOOR STRUCTURE LOCATED BS 695 BL 0 CENTER SECTION IAW B737-700 SRM 51-40-02 AND DWG 273A9112 SHEET 31 REV -. MATERIAL USED: BAC1490-2883; P.O. 2022 17809. SEE INDIVIDUAL SIGNSOFF BELOW.;[03] CORRECTED STEP 2: REPLACED ANGLE FLOOR STRUCTURE LOCATED BS 695 BL 0 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 273A9110 SHEET 6 REV A. MATERIAL USED: BAC1490-2883; P.O. 2022 17809. SEE INDIVIDUAL SIGN OFF BELOW.;[04] CORRECTED STEP 3: REPLACED ANGLE FLOOR STRUCTURE LOCATED BS 695 BL 0 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 273A9110 SHEET 6 REV A. MATERIAL USED: BAC1490-2883; P.O. 2022 178029. SEE INDIVIDUAL SIGN OFF BELOW.;[05] REPLACED ANGLE FLOOR STRUCTURE LOCATED BS 695 BL 0 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 273A9110 SHEET 6 REV A. MATERIAL USED: BAC1490-2883; P.O. 2022 178029. SEE INDIVIDUAL SIGN OFF BELOW.<BR>RII