What was found
CRACK ON INTERCOSTAL- WEB FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA 2023-180823<[01] REPLACED INTERCOSTAL- WEB FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 146A5400 SHEET 26 REV - SEE INDIVIDUAL SIGN OFF BELOW;[02] CERTIFIED AS RII <BR>REPLACED INTERCOSTAL- WEB FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 146A5400 SHEET 26 REV - SEE INDIVIDUAL SIGN OFF BELOW